Turn off any electricity to installation area.
Remove screws and cover from junction box (A) and
set aside for later use.
Remove outer casing and insulation of the hardwiring/
power cord as shown.




8
Loose and improperly installed electrical
connections can result in overheating!
Carefully review terminal block installation
instructions.
To avoid risk of fire, observe the following
precautions:
DO NOT remove, bypass or alter the terminal block.
DO NOT cut or splice the power cord or the
accessory cord
using wire nuts.
Only use the recommended accessory cord for wall
socket connections.
Do not use an extension cord, or any type modified
cord or adapter with this appliance.
WARNING
Attach an approved strain relief (not provided) to oppo-
site side of junction box.
Without adjusting the terminal screws, insert the wires
properly in the terminal. Make sure that the black wire
connects with the black (L) and the white connects with
the white (N) and the green or bare copper wire with the
green (G or ). (See box b)
Do NOT insert wire underneath the screw clamp. (see
box a)
Be certain the wire insulation is not trapped in the termi-
nal. 1-2 mm of wire must be visible (See box b)
After inserting wire, completely tighten the terminal
screws by turning clockwise. (See box c)
After tightening the terminal screws, pull on each wire to
ensure that they are secure. Wire should not be loose in
the terminal after correct installation.
Secure the wire in the junction box with the strain relief.
Note: The arrow (shown in box d above) should align with the
power cord.
9
a
b
cd
1-2 mm
ADVERTENCIA
WARNING
AVERTISSEMENT
STRICTLY FOLLOW ALL INSTRUCTIONS IN THIS MANUAL.
USE ONLY 14 OR 12 AWG COPPER WIRE WITH A MIN. TEMP. RATING
OF 75°C (167°F).
PLACE ALL WIRING IN THE POWER SUPPLY BOX AND INSTALL COVER.
CONNECTION SCREWS ARE NOT REMOVABLE.
ESTRICTAMENTE SIGA TODAS LAS INSTRUCCIONES DE ESTE MANUAL.
UTILICE SÓLO EL 14 O 12 DE ALAMBRE DE COBRE AWG CON UN GRADO
DE LA TEMPERATURA MÍNIMA DE 75 ° C (167 ° F).
COLOQUE TODOS LOS CABLES EN LA CAJA DE LA FUENTE DE ALIMEN-
TACIÓN Y LA INSTALACIÓN DE LA CUBIERTA. TORNILLOS DE CONEXIÓN
NO SON EXTRAIBLES.
WIRE STRIP GAGE
1/2" (13 mm)
CALIBRE DE POUR DÉNUDER
INDICADOR DE CABLE PELADO
OBSERVER TOUTES LES INSTRUCTIONS DE CE GUIDE.
UTILISER SEULEMENT DU FIL DE CUIVRE 14 OU 12 AWG AVEC UNE
COTE DE TEMPÉRATURE MINIMALE DE 75°C (167°F).
PLACER TOUS LES FILS DANS LA BOÌTE D‘ALIMENTATION ET
REMETTRE LE COUVERCLE.
LES VIS DE CONNEXIONS NE SONT PAS AMOVIBLES.
view with cover installed
arrow
strain relief
black (L)
white (N)
green (G)
A
!
Seitenansicht 9