PAGE 5
HEAT SENSOR
Your hood is equipped with a heat sensor that will
turn the blower to Low speed if excessive heat occurs
above the cooking surfaces.
1. If the blower is off – it turns the blower on to low
speed.
2. If the blower is already on any speed selection,
no speed change will occur.
When the temperature level on the hood drops to
normal, the blower will return to its original setting.
Over Temperature Condition - The high
temperature sensor protects the hood from high
temperatures which may damage components. The
control is set to activate at 161º F (72º C) and reset
at 140ºF (60º C). When activated, the ventilator will
turn on low and the corresponding LED will blink,
indicating an over temperature condition.
While the high temperature sensor is activated, the
blower speed can be changed or turned off. If the
blower is turned off, the corresponding LED will blink.
Light controls will remain operational. When the
control sensor reaches 140ºF (60º C), a reset will
occur. During reset, the control will revert back to
the operational state prior to the high temperature
condition.
High Temperature Fault Condition - The circuit
is equipped with an alarm indicating that the heat
sensor protection is not working, due to a damaged
sensor. In the case of this extreme condition, the
three speed indicator LEDs will start blinking. All the
controls will be operational except for the speed
indicators.
OFF
Pressing button once turns ventilator off and resets
control.
FAN SPEED
Pressing button once, from an off state, turns the
ventilator on low. Each successive press of the button
increases the fan speed until high where the fan
cycles back to the low speed.
The LEDs above this button indicate the current
fan speed. When the fan is on, the corresponding
LED is illuminated.
1 – Low
2 – Medium
3 – High
DELAY SHUT OFF
Press to turn fan on high for 10 minutes.
If the ventilator is off when the delay button is
pressed, the ventilator will turn on to the high speed
setting for 10 minutes. At the end of the cycle the
ventilator will turn off.
If the ventilator is on when the delay button is
pressed, the ventilator runs for 10 minutes at the
current speed then turns off.
During a timed period, the LED above the Delay
Shut Off button is illuminated.
To interrupt a timed period, press Fan Speed or
Off button.
CLEAN FILTER REMINDER
After 40 hours of operation, the clean filter reminder
LED above this button will illuminate indicating that
the filters need to be cleaned. When this indicator
illuminates, clean the filters as instructed on page 6.
After cleaning, press this button for 3 seconds to
reset the 40-hour period and turn the LED off.
LIGHT On/Dim/Off
This button controls the halogen lighting. The first
press turns the lights on. A second press dims the
lights. A third press turns the lights off.
HEAT LAMP (for Wall Hoods Only)
The buttons marked “L” and “R” independently control
the left and right infrared heating lamps, turning the
lights on or off.
HOOD CONTROL BUTTONS